Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D
Dräger

Dräger respiratory protection combination filter, Rd40 connection, 940 - A2B2 P2 R D

  • This gas filter complies with EN 14387
  • For masks with standard round thread Rd40 (RA) according to EN 148-1.
  • The filters are optimised in terms of breathing resistance, size and performance.
  • The filters are individually packed to ensure optimal protection of the unused filter. The packaging is resealable for longer use.
  • The aluminium housing allows for good visibility of possible filter damage and thus provides additional safety.
Product features
Manufacturer Dräger
Item number: 101030
Delivery time
Article is in stock - delivery within 48 hours
Prices incl. VAT plus shipping, if applicable.

32,90 € / piece

Product description

 

Synonym for experience and safety

The quality filters of the Dräger X-plore® Rd40 series clean the breathing air of pollutants economically and effectively - whether in the chemical or automotive industry, in shipbuilding, in metal working and processing or in supply and disposal. Suitable for masks with standard round thread Rd40 (RA) according to EN 148-1.
The gas and combination filters have a shelf life of 6 years, the particle filters of 12 years from the date of manufacture.
The filters are individually packaged to ensure optimum protection of the unused filter. The packaging is resealable for longer use.
The aluminium housing allows for good visibility of possible filter damage for added safety.

 

Wide application range

The Dräger filter series X-plore Rd40 with standardised round thread according to EN 148-1 has proven itself many times in practice and offers decisive advantages:

- Extensive range of various filter types for all essential areas of application

- suitable for half and full face masks with connection according to EN 148-1

 

High user safety

- CE certified (EN 141:2000, EN 14387, EN143:2000, EN 371)

- comprehensive filter selection aid programme VOICE

- detailed information leaflets

- filters with aluminium housing with good visibility of possible filter damage

- over 70 years of experience in filter technology

 

High economic efficiency

- individually packed for best protection of the unused filter (incl. instructions for use)

- resealable for longer use

- Shelf life (from date of manufacture):

          ? Gas and combination filters = 6 years

          ? Particle filter = 12 years

 

How do I find the right filter?

Pollutants can occur in different forms, as aerosols (particles or droplets), as gases or vapours. Depending on the form, you need to protect yourself against one of these types or a mixture of them.

          ? Aerosols (particles): Dusts, fibres, fumes, microorganisms (e.g. viruses, bacteria, fungi and their spores) and mists.

          ? Gaseous substances: gases or vapours

The following table shows the colour coding of the filters according to EN 14387, which will help you to choose the right type of filter for use against your pollutant.

individually packed for best protection of the unused filter (incl. instructions for use)

- resealable for longer use

- Shelf life (from date of manufacture):

          ? Gas and combination filters = 6 years

          ? Particle filter = 12 years

 

 

 

Values and calculations have been taken from EN529:2005 and BGR 190. Other national or local regulations must be observed. AGWs were taken as the limit values here. Here, the time-weighted average values over a reference period apply and no short-term limit values.

AX-Filter may only be used in the condition in which they were delivered (fresh from the factory). Reuse and use against gas mixtures is absolutely prohibited.

CO-Filter may only be used once and must be disposed of after use. Instructions according to local guidelines must be followed.

Hg-Filter may only be used for a maximum of 50 hours according to EN14387.

NO-Filter may only be used once and must be disposed of after use.

Reaktor-Filter Instructions according to local guidelines must be followed.

 

Differentiation of filter types

Filters are divided into different classes according to their capacity (gas filters) or their efficiency (particle filters). Class 2 gas filters may be used at higher concentrations or for longer periods than class 1 filters. The class of particle filters indicates how efficiently the filter filters particles out of the ambient air (class 1: 80 %, class 2: 94 %, class 3: 99.95 %).

 

Filtertyp

Filterklasse

Schutz gegen

Höchstzulässige Schadstoffkonzentration

Gasfilter

 

Gase und Dämpfe

 

 

Kapazität:

30 x Grenzwert mit Halbmasken /

400 x Grenzwert mit Vollmasken, jedoch maximal:

 

1

klein

0,1 Vol.-% (1.000 ppm)*

 

2

mittel

0,5 Vol.-% (5.000 ppm)*

 

3

groß

1,0 Vol.-% (10.000 ppm)*

Partikelfilter

 

Partikeleffizienz (Abscheideleistung

 

1

klein

4 x Grenzwert**

 

2

Mittel

10 x Grenzwert mit Halbmasken /

15 x Grenzwert mit Vollmasken**

 

3

groß

30 x Grenzwert mit Halbmasken /

400 x Grenzwert mit Vollmasken**

 

Beispiel:

Bleistaub MAK = 0,1 mg/m3 4 × 0,1 mg/m3 = 0,4 mg/m3 = max. erlaubte Konzentration von Bleistaub beim Gebrauch von P1-Filtern.

Advantages

Advantages

  • Comprehensive advice on all products
  • Official Dräger, Honeywell, MSA and uvex dealer
  • Extensive product range from brand manufacturers
  • Supply of accessories etc. on request
  • Occupational safety products as well as gas and alcohol measuring technology
  • No shipping costs from 50€ (for Germany and Austria)
  • More than 400,000 satisfied customers
  • Secure payment via credit card, PayPal, Amazon Pay etc.
  • Convenient delivery with DHL, DPD etc.
  • Service for breathalysers and gas detection technology
  • Individualisation of workwear
  • Many of ACE's own products in the fields of breathalysers and occupational health and safety
Back

By creating an account with our shop, you will be able to move through the checkout process faster, be up to date on an orders status, and keep track of the orders you have previously made.

Register
Back
The shopping cart is still empty.
{{ productName }} is not discountable

{{ added.quantity }}x {{ added.item.name }} was added to your shopping cart.

To the checkout Edit shopping cart
Voucher ():
Subtotal
Missing up to the free shipping limit
0,00€
To the checkout Edit shopping cart Payment with PayPal
Back